Liquidyne's High-Performance Burkert FLOWave 8098 Flow Meter
If you're seeking the next-generation flow measurement solution for hygienic, highly efficient processes, the Burkert FLOWave 8098 flow meter is a standout choice. Designed with unique SAW (Surface Acoustic Wave) technology, the FLOWave 8098 excels in industries such as food and beverage, pharmaceuticals, biotechnology, and any application that requires reliable inline measurement under strict hygienic conditions. Its non-intrusive design, compact footprint, and easy-to-clean construction make it the premier choice for manufacturers who want to improve product yields, reduce waste, and enhance overall productivity. At Liquidyne, we proudly offer the FLOWave 8098 flow meter to help you outpace your competition with a highly accurate, space-saving, and future-proof flow measurement device.
Overview and Uses
Traditional electromagnetic or Coriolis flow meters often come with bulky footprints, moving parts, or internal obstructions that can cause unwanted pressure drops and maintenance headaches. In contrast, the FLOWave 8098 flow meter is built around an unobstructed stainless-steel measuring tube with no sensor elements in contact with the medium. This non-contact approach eliminates risk points for contamination or leakage, making it ideal for Clean-in-Place (CIP) and Sterilize-in-Place (SIP) operations.
The key uses and applications for this meter include:
-
Food and Beverage Production
- Milk, beer, juices, flavored drinks, and syrups
- Accurate flow tracking for batch processes
- Minimized product loss when switching between media
-
Pharmaceutical and Biotech
- Sterile fluid-handling scenarios
- High-purity water systems, solutions, and suspensions
- Real-time, non-contact flow measurement to ensure product integrity
-
Chemical and Cosmetics
- Viscous liquids, light suspensions, or fluids with varying conductivity
- High reliability and consistency for sensitive production lines
-
General Hygienic Environments
- Any context requiring CIP or SIP routines
- Processes demanding minimal pressure drops
This broad applicability gives the FLOWave 8098 flow meter the flexibility to serve as a workhorse solution across diverse market sectors.
Thanks to the compact, light design—especially compared to Coriolis meters of equivalent capacity—operators can expect simpler installation and lower overall operating costs. Whether handling dairy products, pharmaceuticals, or CIP media, the FLOWave 8098 adapts seamlessly to changing fluids, quickly distinguishing one media type from another to reduce losses.
Sizes, Connection Options, and Customizations
One of the standout attributes of the FLOWave 8098 flow meter is its array of connection sizes and types to match both local and global standards:
- DIN 32676 Clamp Connections (Series A, B, or C)
- DIN 11864 Aseptic Collar Flange/Clamp
- ASME BPE Clamp
- DIN 11851 Thread
- SMS 3008 / 3017 Clamp
Standard nominal diameters range from DN08 to DN80 (3/8" to 3"), supporting flow rates as high as 200 m³/h. You can also customize options for:
- Surface Finish: Choose between Ra <0.8 µm or Ra <0.4 µm (electro-polished)
- ATEX/IECEx or HazLoc (UL) Approvals: For use in explosion-hazard environments
- Advanced Outputs: Select from analog, digital (pulse/frequency), IO-Link, or industrial communication protocols such as PROFINET, EtherNet/IP, or EtherCAT
- Density and Mass Flow: Optional features for integrated, real-time mass flow calculations
This modular approach ensures you receive a device finely tuned to your production environment and compliance requirements. Whether you prioritize 3-A certification, CIP-friendly design, or high-level software integration, Liquidyne can deliver a FLOWave 8098 that matches your precise needs.
How the FLOWave 8098 Outpaces Competitive Products
-
No Flow Obstructions
Unlike electromagnetic flowmeters with inline electrodes or Coriolis meters with bulky tubes, the FLOWave 8098 has no internal components in the flow path. This results in virtually zero pressure drop, simpler cleaning, and reduced contamination risk. -
Rapid Media Changeover Detection
The proprietary "Differentiation Factor" (DF) and "Acoustic Transmission Factor" (ATF) let you switch from one medium to another quickly with minimal waste. Each time you rinse with water or a cleaning agent, the meter instantly pinpoints the new fluid, drastically reducing product giveaway. -
Unmatched Hygienic Design
It seamlessly fits into sterile and ultra-clean processes and is compliant with 3-A, EHEDG, and FDA standards. The stainless-steel body is free of internal grooves or crevices, meeting the top hygienic requirements in food and pharmaceuticals. -
Lightweight and Compact
Flow meters based on Coriolis principles often weigh tens of kilograms at the same flow rate. The FLOWave 8098 can weigh under 5 kg in smaller diameters, saving space and easing installation or maintenance on high-level platforms and tight production lines. -
Future-Ready Digital Communication
Modern plants demand robust data exchange. The 8098 can be integrated into nearly any Industrial Ethernet or fieldbus architecture, whether you rely on Modbus TCP, EtherNet/IP, EtherCAT, or PROFINET. The ability to upgrade firmware ensures your meter stays current with evolving Industry 4.0 standards. -
Versatile for Low and Non-Conductive Liquids
Since SAW-based measurement does not rely on conductivity (unlike electromagnetic meters), you can measure deionized water, solvents, or liquids with extremely low conductivity levels. The flow meter maintains accuracy across a wide range of media properties.
Conclusion
Regarding an advanced, flexible, and genuinely hygienic flow measurement solution, the Burkert FLOWave 8098 flow meter stands in a class by itself. Its SAW technology delivers precise results in low or non-conductive liquids, while its smooth stainless-steel tube remains free from obstructions or dead zones. With a single device, you'll dramatically reduce product loss during media transitions and meet global compliance standards. With Liquidyne's unmatched customer support and customization expertise, the FLOWave 8098 offers a comprehensive, future-focused flow metering solution to help your operations run more profitably and reliably.
- Non-Contact Measurement
Uses no internal sensor elements in the liquid flow path - Easy Installation and Handling
Compact, lightweight design for tight piping configurations - Integrated Functions
Offers density measurement, temperature reading, DF (Differentiation Factor), ATF (Acoustic Transmission Factor), and advanced diagnostics - Higher Process Efficiency
Rapid detection of different media during changeovers - Flexible Output Protocols
Supports standard 4–20 mA and digital interfaces like IO-Link, EtherNet/IP, PROFINET, and Modbus TCP - Certified Hygienic Compliance
Meets 3-A, EHEDG, and FDA standards for regulated environments - Simple Maintenance
Designed without obstructions, moving parts, or crevices
- Reduced Contamination Risks
Why? No internal sensor elements come into contact with the medium, cutting down on cleaning times and potential bacterial buildup. - Minimal Setup and Labor Costs
Why? Lightweight, compact construction means easier installation, fewer support structures, and less downtime. - Better Process Control
Why? Real-time metrics (density, temperature, differentiation factor, acoustic transmission factor) give you deeper insight and faster responsiveness. - Lower Product and Chemical Waste
Why? Quick detection of fluid changeovers reduces unnecessary disposal of cleaning agents and product. - Seamless System Integration
Why? Multiple output protocols simplify connectivity with SCADA, MES, or other industrial automation systems. - Strict Hygiene Assurance
Why? Industry certifications and zero internal sensors help maintain top-tier sanitary conditions and avoid cross-contamination. - Long-Term Cost Savings
Why? Fewer wearing components equate to minimal servicing needs, decreased downtime, and reduced overall lifecycle expenses.
- Technology: Surface Acoustic Wave (SAW)
- Sizes (Nominal Diameters): DN08 through DN80, and 3/8" through 3"
- Flow Ranges: Up to 200 m³/h (depending on nominal diameter)
- Accuracy: ±0.4% of measured value (from 10% to full-scale flow)
- Hygienic Standards: 3-A, EHEDG, FDA compliance for wetted materials
- Material: All wetted parts in 316L stainless steel (low delta ferrite)
- Media Conductivity: Works with low or non-conductive fluids
- Density Measurement (Optional): For mass flow calculations, ±1% after teach-in
- Temperature Range: –20 °C to +140 °C (–4 °F to +284 °F)
- Pressure Rating: Up to 25 bar, depending on diameter and connection
- Communication: Options include standard analog and digital outputs, IO-Link, PROFINET, EtherNet/IP, Modbus TCP, EtherCAT, and more
Related Products
At Liquidyne, we prioritize our commitment to quality and consistency. In 2017 we achieved ISO 9001:2015 Quality Management System certification to ensure we can repeatedly deliver consistently high-quality products and solutions. Being ISO 9001:2015 QMS Certified by Amtivo (USA), Inc, together with our USP Class VI Testing, ASME Bioprocessing Equipment (BPE), and EHEDG certification guarantee, we have the methodologies to assure quality. We will quickly and accurately rectify any issues if any of our products are ever in non-conformance.