CPC HFC Disconnect Series Bodies HFCD17439MHC
The HFCD17439MHC in the CPC HFC Disconnect Series represents an advanced solution for facilitating sterile disconnections within single-use manufacturing systems critical to the biopharmaceutical and cell and gene therapy sectors. This 1/4" Hose Barb Valved Body is engineered with Alloy C-276, optimizing it for the high demands of sterile process environments. It offers a straightforward disconnection mechanism via a thumb latch, ensuring sterility is preserved throughout the disconnection process, a key advantage in maintaining product integrity and safety.
Constructed from high-quality polysulfone with an amber tint, the HFCD17439MHC complies with the stringent standards set by USP Class VI and ADCF, highlighting its suitability for sensitive applications. The device’s compatibility with up to 75 psi (5.17 bar) of pressure and operational temperatures ranging from 34°F (1°C) to 104°F (40°C) makes it versatile across various manufacturing settings. Its design includes platinum-cured silicone O-rings and Alloy C-276 flow path springs, ensuring chemical resistance, durability, and reliability under repeated sterilization cycles, whether by gamma radiation up to 50 kGy or autoclave up to 270°F (132°C) for 60 minutes.
Beyond its technical specifications, the HFCD17439MHC is sold as part of a connected set that features a protective thumb latch cover, effectively eliminating the risk of unintended disconnections. Each unit is meticulously laser-etched with an item and lot number, ensuring full traceability for batch processes. This careful attention to detail affirms the HFCD17439MHC’s role as an indispensable component in the toolkit of professionals striving for excellence in manufacturing processes requiring uncompromised sterility and reliability.
Features
- Intuitive one-step disconnection process
- Ease of connectivity
- Audible "click"
- Protective thumb latch cover
- Laser etched item number and lot number
- Alloy C-276 internal flow path spring
Benefits
- Minimize operation error and eases standard operation procedure creation and training
- No requirement for additional equipment to make sterile disconnection
- Provides confidence of a secure connection
- Eliminate accidental disconnects
- Full traceability to raw material source
- Enabling broader application compatibility
Polysulfone, USP Class VI, ADCF
Material Finish:
Natural
Pressure Range:
Vacuum to 75 psi, 5.17 bar
Color:
Amber tint
Mounting Option:
Free Floating
Sterilization:
Gamma, autoclave
Temperature Range:
-40¡F - 280¡F (-40¡C - 138¡C)
Seal Options:
Silicone, platinum-cured, USP Class VI, ADCF
Valve Spring:
ALLOY C-276
Valve Option:
Valved
Pressure: Up to 75 psi, 5.17 bar
Temperature: 34¡F (1¡C) to 104¡F (40¡C)
Materials:
Main components:
Polysulfone (amber tint), USP Class VI, ADCF
O-rings:
Silicone (clear), platinum cured, USP Class VI, ADCF
Flow Path Springs: Alloy C-276
Sterilization:
Gamma: Up to 50 kGy gamma irradiation. Sterilize coupled or uncoupled.
Autoclave:
Up to 270¡F (132¡C) for 60 minutes. One cycle
WARNING: Pressure, temperature, chemicals and operating environment can affect the performance of couplings. It is the customerÕs responsibility to test the suitability of Colder products in their own application conditions.
Related Products
At Liquidyne, we prioritize our commitment to quality and consistency. In 2017 we achieved ISO 9001:2015 Quality Management System certification to ensure we can repeatedly deliver consistently high-quality products and solutions. Being ISO 9001:2015 QMS Certified by Orion Registrar, Inc, together with our USP Class VI Testing, ASME Bioprocessing Equipment (BPE), and EHEDG certification guarantee, we have the methodologies to assure quality. We will quickly and accurately rectify any issues if any of our products are ever in non-conformance.